SERVICESFIRE COMPARTMENTATION, FIRESTOPPING, DOORS & CURTAINS
Technician applying UL-listed firestop sealant around cable tray penetration
05

Fire Compartmentation, Firestopping, Doors & Curtains

SIMPLE DESCRIPTION

Fire compartmentation divides a building into designated fire-resisting areas. Firestopping, fire-rated doors and fire curtains help maintain these barriers and restrict the spread of fire and smoke through openings, joints and access points.

HOW IT WORKS

Fire-resisting walls and floors create physical barriers between building compartments. Firestopping materials seal openings and construction joints around building services, while fire-rated doors and curtains protect designated openings. Together, these systems help maintain the intended fire-resistance performance of the building.

KEY BENEFITS
Helps limit fire and smoke spread between compartments.
Protects cable, pipe and other service penetrations.
Maintains the integrity of fire-rated walls and floors.
Supports protected escape routes and building safety.
Provides passive protection for essential building areas.
WHERE TO APPLY IT
Cable, cable tray and pipe penetrations.
Construction and movement joints.
Fire-rated walls and floor openings.
Staircases and protected corridors.
Electrical and mechanical service rooms.
Factories, warehouses and industrial facilities.
Shopping malls, hospitals, hotels and high-rise buildings.
FIRE-RESISTANCE RATING

Up to 4 hours, depending on the tested system

Firestopping: Commonly 60, 90, 120, 180 and up to 240 minutes, depending on the tested penetration or joint system.

Fire-rated doors: Common ratings include 20, 30, 45, 60, 90 and 120 minutes, with other ratings available for specific systems.

Fire-rated curtains: Performance and duration depend on the tested curtain assembly.

Fire compartmentation: Required wall and floor ratings are determined by the building design and applicable code requirements.

SYSTEM SPECIFICATION & STANDARDS
Fire-rated penetration sealing systems.
Fire-resistant sealants, mortars, wraps and collars.
Linear joint and perimeter firestopping systems.
Fire-rated doors, frames, hardware and accessories.
Fire-rated curtains and barrier systems.
ASTM E814, UL 1479, UL 2079, EN 1366-3, EN 1366-4, EN 1634-1 and BS 8524, where applicable.
SYSTEM TYPEPenetration Seals / Doors / Curtains
FIRE RATINGUp to 4 HR (System-dependent)
STANDARDSASTM E814 / UL 1479 / EN 1366-3 / EN 1634-1
DELIVERABLENumbered penetration register
FREQUENTLY ASKED QUESTIONS

What documentation is delivered after firestopping installation?

Every sealed penetration and linear joint is logged in a numbered penetration register with system references, product datasheets and inspection records for handover.

Which standards cover your firestopping, doors and fire curtains?

Applicable systems are tested to ASTM E814, UL 1479, UL 2079, EN 1366-3, EN 1366-4, EN 1634-1 and BS 8524, aligned with BNBC 2020 Part 4.

Fire & Smoke Control Dampers

Specifying PFP for a project?

Free site assessment: ratings review, scope outline and budget figures within one week.

REQUEST A QUOTE