SERVICESINTUMESCENT FIREPROOFING (IFRM)
Spray application of thin-film intumescent coating on structural steel beam
02

Intumescent Fireproofing (IFRM)

SIMPLE DESCRIPTION

Intumescent Fire-Resistive Material (IFRM) is a specialized coating applied to structural steel to provide fire protection while maintaining its original shape and architectural appearance.

HOW IT WORKS

When exposed to high temperatures, the coating expands and forms a thick insulating char layer. This layer slows heat transfer to the steel, helping protect its structural capacity during fire exposure.

KEY BENEFITS
Provides fire protection with relatively thin coatings.
Maintains the architectural appearance of exposed steel.
Suitable for complex structural steel profiles.
Available in different finishes and coating technologies.
Suitable for projects requiring aesthetic and functional protection.
WHERE TO APPLY IT
Structural steel beams and columns.
Exposed architectural steel structures.
Shopping malls, hotels and airports.
Commercial and high-rise buildings.
Industrial and institutional facilities.
FIRE-RESISTANCE RATING

Up to 4 hours (240 minutes), where supported by tested systems

Typical ratings may include 30, 60, 90, 120, 180 and 240 minutes.

The required dry film thickness (DFT) depends on the coating system, steel section factor, critical steel temperature and approved assessment.

SYSTEM SPECIFICATION & STANDARDS
Thin-film or thick-film intumescent coating systems.
Water-based, solvent-based or epoxy-based products.
Compatible primer and protective topcoat, where required.
DFT calculated using the selected product's approved assessment.
ASTM E119, UL 263, EN 13381-8 and EN 13501-2.
SYSTEM TYPEThin / Thick-Film IFRM
FIRE RATING30 to 240 min (Up to 4 HR)
STANDARDSASTM E119 / UL 263 / EN 13381-8
FINISHExposed architectural grade
FREQUENTLY ASKED QUESTIONS

How is the required intumescent dry film thickness (DFT) determined?

The required DFT is calculated from the selected product's approved fire test assessment based on the steel section factor (Hp/A), critical steel temperature and target fire-resistance duration.

Can intumescent coatings be used on exposed lobby or atrium steelwork?

Yes. IFRM maintains the clean profile and architectural appearance of exposed steel and can be finished with a compatible protective topcoat.